PARAMEDIC SERIES AED AUTOMATED EXTERNAL DEFIBRILLATOR – CU-ER1
FEATURES:
- Automatic analysis of patient ECG.
- User guide with text and voice prompts.
- 320 X 240 graphic LCD display.
- Versatile Power Supply, rechargeable battery pack and AC adapter standard.
- Car cigar lighter jack power cord and disposable battery pack optional.
- Battery has capacity of 200 shocks when fully charged.
- Rescue data collected is stored in internal flash memory.
- Rescue data can be downloaded for review, archiving and printing.
Automatic self tests, prompts and alarms given if device fails self tests.
Description
MODEL |
CU-ER1 |
ECG Function |
– Patient connection: Defibrillation Pads, ECG Electrodes. – Bandwidth: Monitoring Mode: 0.3 to 40Hz (-3dB) EMS Mode – 1~30Hz – ECG size: 5,10, 20mm/mV display on monitor ( Auto scaling) – Heart rate: Digital 30 to 300 bpm (±2%) |
Defibrillator |
– Operation mode: Semi automatic – Waveform: e-cube biphasic (Truncated exponential type) – Energy: 150J into 50Ω load (default setting) Preprogrammed selection (150J-150J-180J,150J-180J-180J) – Charging time: Less than 10 seconds – Recognition: Sensitivity and Specificity = 99.5% – Detection Level: > 0.1mV ECG – Defibrillation Electrodes: Multifunction electrodes (Disposable) Adult adhesive pads (pre-gelled) |
Voice and Text Prompts |
– Voice and text prompts guide the user through the protocol – All the user interfaces are supported in local language for easy use. |
Data Storage & Management |
– Internal flash memory: 10 hours of event and ECG recording – SmartMedia Card (32M): 48 hours of event and ECG recording or 1 hour if voice recording is enabled. |
Automated Self-Test |
– Power On Self-Test / Run Time Self-Test / Manual Test – Periodic Self-Tests (daily / weekly / monthly) |
Display |
– Screen Type: High resolution display (graphic LCD) – Screen size: 4 inches diagonal, 320×240 pixels – Sweep speed: 25mm/sec, nominal – Viewing time: 3.2 seconds |
Physical |
– Size: 305mm x 250mm x 95mm (L x W x H) – Weight: Approximately 2.8Kg – Galvanic Protection: BF type |
AC Adaptor |
– Input: 100 ~ 240V AC 50/60Hz 1.2A – Output: + 12VDC, 3.5A |
Battery Pack |
– 12V Nickel-Metal Hydride battery pack (rechargeable) – Charging time: Minimum of 4 hours for full charging – Capacity: when new, minimum of 200 shocks deliveries (fully charged) |
External Link |
– UART port – IrDA port |
Package Contents |
– Device, 1 Sets of pads, 1 Power Cord, 1 AC Adapter, 1 Long Life NI-MH battery, 1 Operator’s Manual, 1 Quick Reference Card, Carrying Case |
Optional Accessories |
– Car Cigar Lighter Jack Power Cord – SmartMedia Card (32M) – External Thermal Printer (wire) and paper – UART Cable / ECG Cable (3 lead) / ECG Electrodes. |